Microphone
Microphone

Microphone

Model: ∅6.0x2.7 Hyper-cardioid
Product Detail

SPECIFICATIONS

Item

Symbol

Test conditions

Min

Standard

Max

Unit

Sensitivity

S

f = 1KHz.Pi n = 1Pa 0dB=1V/Pa

-40

-38

-36

dB

Directivity

Hyper-cardioid

Output Impedance

Zout




2.2

Maximum input S.P.L


f = 1KHz.THD<3%



110

dB

Signal to Noise Ratio0°~ 135°


F=1KHz,S.P.L=1Pa

12


dB

Operational Voltage

Vs

-

1.0

2.0

10.0

V

Current Consumption

I

f = 1KHz.Pin = 1Pa

150


450

uA

Sensitivity Reduction

S

f = 1KHz.Pin = 1Pa

Vs =3.0→2.0V



-3

dB

S/N Ratio

S/N

f = 1KHz.Pi n = 1Pa

A = curve


62


dB

DIMENSION:

602738.png

Inquiry Now